Skip to main content
icon-play
Videos

Implant and Abutment Surfaces

Video highlights

  • Factors controlling osseointegration
  • Influences of implant surfaces
  • Influences of abutment surfaces
  • New surfaces on implants and abutments

References

[1] Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52(2):155-70. doi: 10.3109/17453678108991776. PMID: 7246093.

[2] Wennerberg A, The importance of surface roughness for implant incorporation, International Journal of Machine Tools and Manufacture, Volume 38, Issues 5–6, 1998, Pages 657-662, ISSN 0890-6955, https://doi.org/10.1016/S0890-6955(97)00114-4.

[3] Daftary F, Mahallati R, Bahat O, Sullivan RM. Lifelong craniofacial growth and the implications for osseointegrated implants. Int J Oral Maxillofac Implants. 2013 Jan-Feb;28(1):163-9. doi: 10.11607/jomi.2827. PMID: 23377062.

[4] Evans CD, Chen ST. Esthetic outcomes of immediate implant placements. Clin Oral Implants Res. 2008 Jan;19(1):73-80. doi: 10.1111/j.1600-0501.2007.01413.x. Epub 2007 Oct 22. PMID: 17956569.

[5] Henry PJ, Liddelow GJ. Immediate loading of dental implants. Aust Dent J. 2008 Jun;53 Suppl 1:S69-81. doi: 10.1111/j.1834-7819.2008.00044.x. PMID: 18498588.

[6] Henry PJ, Depiazzi J, Liddelow GJ, Allan B, Dunn D, Utilisation of computer based Nobelguide in the management of partial edentulism. International Dentistry 2007; 2: 42-53

[7] Wilson TG Jr. The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study. J Periodontol. 2009 Sep;80(9):1388-92. doi: 10.1902/jop.2009.090115. PMID: 19722787.

[8] Wittneben JG, Millen C, Brägger U. Clinical performance of screw- versus cement-retained fixed implant-supported reconstructions--a systematic review. Int J Oral Maxillofac Implants. 2014;29 Suppl:84-98. doi: 10.11607/jomi.2014suppl.g2.1. PMID: 24660192.

[9] Wilson TG Jr. The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study. J Periodontol. 2009 Sep;80(9):1388-92. doi: 10.1902/jop.2009.090115. PMID: 19722787.

[10] Atieh MA, Ibrahim HM, Atieh AH. Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. J Periodontol. 2010 Oct;81(10):1350-66. doi: 10.1902/jop.2010.100232. PMID: 20575657.

[11] Canullo L, Rasperini G. Preservation of peri-implant soft and hard tissues using platform switching of implants placed in immediate extraction sockets: a proof-of-concept study with 12- to 36-month follow-up. Int J Oral Maxillofac Implants. 2007 Nov-Dec;22(6):995-1000. PMID: 18271382.

[12] López-Marí L, Calvo-Guirado JL, Martín-Castellote B, Gomez-Moreno G, López-Marí M. Implant platform switching concept: an updated review. Med Oral Patol Oral Cir Bucal. 2009 Sep 1;14(9):e450-4. PMID: 19718008.

[13] Linkevicius T, Puisys A, Steigmann M, Vindasiute E, Linkeviciene L. Influence of Vertical Soft Tissue Thickness on Crestal Bone Changes Around Implants with Platform Switching: A Comparative Clinical Study. Clin Implant Dent Relat Res. 2015 Dec;17(6):1228-36. doi: 10.1111/cid.12222. Epub 2014 Mar 28. PMID: 24673875.

[14] Gamborena I, Sasaki Y, Blatz MB. Transmucosal abutments in the esthetic zone: Surgical and prosthetic considerations. J Esthet Restor Dent. 2023 Jan;35(1):148-157. doi: 10.1111/jerd.13006. Epub 2023 Jan 11. PMID: 36628558.

[15] Souza AB, Tormena M, Matarazzo F, Araújo MG. The influence of peri-implant keratinized mucosa on brushing discomfort and peri-implant tissue health. Clin Oral Implants Res. 2016 Jun;27(6):650-5. doi: 10.1111/clr.12703. Epub 2015 Oct 16. PMID: 26474541.

[16] Lin GH, Chan HL, Wang HL. The significance of keratinized mucosa on implant health: a systematic review. J Periodontol. 2013 Dec;84(12):1755-67. doi: 10.1902/jop.2013.120688. Epub 2013 Mar 1. PMID: 23451989.

[17] Baqain ZH, Moqbel WY, Sawair FA. Early dental implant failure: risk factors. Br J Oral Maxillofac Surg. 2012 Apr;50(3):239-43. doi: 10.1016/j.bjoms.2011.04.074. Epub 2011 May 25. PMID: 21612850.

[18] Thoma DS, Naenni N, Benic GI, Hämmerle CH, Jung RE. Soft tissue volume augmentation at dental implant sites using a volume stable three-dimensional collagen matrix - histological outcomes of a preclinical study. J Clin Periodontol. 2017 Feb;44(2):185-194. doi: 10.1111/jcpe.12635. Epub 2017 Jan 3. PMID: 27716970.

[19] Thoma DS, Mühlemann S, Jung RE. Critical soft-tissue dimensions with dental implants and treatment concepts. Periodontol 2000. 2014 Oct;66(1):106-18. doi: 10.1111/prd.12045. PMID: 25123764.

[20] Thoma DS, Buranawat B, Hämmerle CH, Held U, Jung RE. Efficacy of soft tissue augmentation around dental implants and in partially edentulous areas: a systematic review. J Clin Periodontol. 2014 Apr;41 Suppl 15:S77-91. doi: 10.1111/jcpe.12220. PMID: 24641003.

[21] Kan JYK, Yin S, Rungcharassaeng K, Zucchelli G, Urban I, Lozada J. Facial implant gingival level and thickness changes following maxillary anterior immediate tooth replacement with scarf-connective tissue graft: A 4-13-year retrospective study. J Esthet Restor Dent. 2023 Jan;35(1):138-147. doi: 10.1111/jerd.12996. Epub 2022 Dec 13. PMID: 36511151.

[22] Milleret V, Lienemann PS, Bauer S, Ehrbar M. Quantitative in vitro comparison of the thrombogenicity of commercial dental implants. Clin Implant Dent Relat Res. 2019 Mar;21 Suppl 1:8-14. doi: 10.1111/cid.12737. Epub 2019 Feb 28. PMID: 30816636.

[23] Roffel S, Wu G, Nedeljkovic I, Meyer M, Razafiarison T, Gibbs S. Evaluation of a novel oral mucosa in vitro implantation model for analysis of molecular interactions with dental abutment surfaces. Clin Implant Dent Relat Res. 2019 Mar;21 Suppl 1(Suppl Suppl 1):25-33. doi: 10.1111/cid.12750. Epub 2019 Mar 12. PMID: 30859688; PMCID: PMC6594065.

[24] Susin C, Finger Stadler A, Musskopf ML, de Sousa Rabelo M, Ramos UD, Fiorini T. Safety and efficacy of a novel, gradually anodized dental implant surface: A study in Yucatan mini pigs. Clin Implant Dent Relat Res. 2019 Mar;21 Suppl 1:44-54. doi: 10.1111/cid.12754. Epub 2019 Mar 12. PMID: 30860675.

[25] Rompen E, Domken O, Degidi M, Pontes AE, Piattelli A. The effect of material characteristics, of surface topography and of implant components and connections on soft tissue integration: a literature review. Clin Oral Implants Res. 2006 Oct;17 Suppl 2:55-67. doi: 10.1111/j.1600-0501.2006.01367.x. PMID: 16968382.

[26] Touati B. Ethics in treatment planning. Pract Proced Aesthet Dent. 2005 Mar;17(2):90. PMID: 15918299.

[27] Schupbach P, Glauser R. The defense architecture of the human periimplant mucosa: a histological study. J Prosthet Dent. 2007 Jun;97(6 Suppl):S15-25. doi: 10.1016/S0022-3913(07)60004-3. Erratum in: J Prosthet Dent. 2008 Mar;99(3):167. PMID: 17618929.

[28] Hall J, Neilands J, Davies JR, Ekestubbe A, Friberg B. A randomized, controlled, clinical study on a new titanium oxide abutment surface for improved healing and soft tissue health. Clin Implant Dent Relat Res. 2019 Mar;21 Suppl 1:55-68. doi: 10.1111/cid.12749. Epub 2019 Mar 12. PMID: 30859691.

[29] Fabbri, G. and Ban, G. (2020), Clinical study with gradually anodized implants restored with two-piece anodized abutments – preliminary results. Clin Oral Impl Res, 31: 285-285. https://doi.org/10.1111/clr.223_13644

[30] Fabbri G, Staas T, Linkevicius T, Valantiejiene V, González-Martin O, Rompen E. Clinical Performance of a Novel Two-Piece Abutment Concept: Results from a Prospective Study with a 1-Year Follow-Up. J Clin Med. 2021 Apr 9;10(8):1594. doi: 10.3390/jcm10081594. PMID: 33918898; PMCID: PMC8070442.

[31] Feller L, Jadwat Y, Khammissa RA, Meyerov R, Schechter I, Lemmer J. Cellular responses evoked by different surface characteristics of intraosseous titanium implants. Biomed Res Int. 2015;2015:171945. doi: 10.1155/2015/171945. Epub 2015 Feb 12. PMID: 25767803; PMCID: PMC4341860.

[32] Jemt T, Olsson M, Franke Stenport V. Incidence of First Implant Failure: A Retroprospective Study of 27 Years of Implant Operations at One Specialist Clinic. Clin Implant Dent Relat Res. 2015 Oct;17 Suppl 2:e501-10. doi: 10.1111/cid.12277. Epub 2014 Dec 23. PMID: 25536273.

[33] Karl M, Albrektsson T. Clinical Performance of Dental Implants with a Moderately Rough (TiUnite) Surface: A Meta-Analysis of Prospective Clinical Studies. Int J Oral Maxillofac Implants. 2017 Jul/Aug;32(4):717-734. doi: 10.11607/jomi.5699. PMID: 28708905.

[34] Kang BS, Sul YT, Oh SJ, Lee HJ, Albrektsson T. XPS, AES and SEM analysis of recent dental implants. Acta Biomater. 2009 Jul;5(6):2222-9. doi: 10.1016/j.actbio.2009.01.049. Epub 2009 Feb 7. PMID: 19261554.

Clinical topics

Implant surfaces

Questions

Log in or register to post questions and answers.
Ask a question
Hide answers
Anonymous
25.02.2024 | 22:57

Do you have an opinion concerning the use of water pick around implants, especially older non-Zeal surface implants.

I have seen patients of mine that have had stable implants close to 15 years starting to show sudden marginal bone loss months after the use of a waterpik.  I have always been nervous having the roughened implant surface carried up to the implant collar.

Show Answers

I have seen patients of mine that have had stable implants close to 15 years starting to show sudden marginal bone loss months after the use of a waterpik.  I have always been nervous having the roughened implant surface carried up to the implant collar.

Profile picture for user glenliddelow

I haven't seen any sudden bone loss with the use of a waterpik in fact, we actively recommend the use of a waterjet device especially for full arch rehabilitations and have noted greatly improved plaque control. If the periimplant mucosa was especially thin and the patient was quite aggressive with the jet then maybe? We have seen bone loss with floss pieces wrapped around the abutment.

I agree that having a rough surface at the collar is not ideal particularly  for patients with a higher risk profile for peri-implantitis so have tended to favour the PMC collar with TiUnite and now the TiUltra surface.  

Hide answers
10.05.2024 | 20:17

What camera and photography system you use and follow please The photos are amazing

.i have used ring flash and images are not sharp as well with Canon camera and lens. 

Show Answers

.i have used ring flash and images are not sharp as well with Canon camera and lens. 

Profile picture for user glenliddelow

Thankyou! I use a Canon 5DS with 100mm redband macro and Canon twin flash and  intra.diffuser kit from intra.photos for most of the aesthetic photos. Ringflash for surgery generally.

Intraphotos also have online dental photography courses run by Szabi Hant - one of the most talented dental technicians and photographer I've seen. That may sort out any problems.

I hope that helps!